HEALTH NEWS

Study Title:

WHO Guidelines for Indoor Air Quality: Selected Pollutants.

Study Abstract

Formaldehyde (molecular formula H2-C=O; CAS number 50-00-0) is a colourless gas, flammable and highly reactive at room temperature. Formaldehyde can also be obtained commercially as a 30–50% (by weight) aqueous solution, known as formalin.

In ambient air, formaldehyde is quickly photo-oxidized in carbon dioxide. It also reacts very quickly with the hydroxyl radicals to give formic acid. The half-life estimated for these reactions is about one hour depending on the environmental conditions.

The main chemical and physical properties (of the pure substance) are as follows (1,2): molecular mass 30.03 g/mol; relative vapour density 1.03–1.07 (air = 1); melting point −92 °C; and boiling point −19.1 °C. Formaldehyde is soluble in water (around 400 g/l at 20 °C), ethanol and chloroform and miscible with acetone, benzene and diethylether. The octanol/water partition coefficient (log Kow) is 0.35, the vapour pressure is 5.19 × 105 Pa at 25 °C and the Henry's Law constant is 3.41 × 10−2 Pa.m3/mol at 25 °C.

Formaldehyde is ubiquitously found in the environment, because it is formed primarily by numerous natural sources and anthropogenic activities. In the environment, it is released through biomass combustion (forest and bush fires) or decomposition and through volcanoes, for example. Anthropogenic sources include direct ones such as on-site industrial emissions and fuel combustion from traffic. Other combustion processes (power plants, incineration, etc.) also represent sources of formaldehyde emissions in the atmosphere. However, formaldehyde is also extensively produced industrially worldwide for use in the manufacture of resins, as a disinfectant and fixative, or as a preservative in consumer products.

All these man-made products and uses are the major indirect sources of formaldehyde, in particular indoors. Finally, it should be noted that secondary formation of formaldehyde occurs in air through the oxidation of volatile organic compounds (VOCs) and reactions between ozone (mainly from outdoors) and alkenes (especially terpenes) have been widely described. The contribution of these secondary chemical processes to the ambient and indoor concentrations is still not fully quantified.

Common techniques to measure formaldehyde concentrations include both integrated active and passive methods. Formaldehyde is generally trapped on a sorbent impregnated with 2,4-dinitrophenylhydrazine (2,4-DNPH). Analysis is then conducted in the laboratory by high-performance liquid chromatography and ultraviolet detection at 350 nm. Detection and quantification limits around 1 μg/m3 can be achieved. The use of an ozone scrubber is recommended to remove the latter from the sample stream to prevent interference during the analysis. Recent comparisons of formaldehyde measurement techniques have shown that, in the presence of low relative humidity, 2,4-DNPH-based methods could underestimate concentrations (3,4).